please help me make a checklist for this fire alarm euips.. checklist for parts will be best.. thanks guys.. please i need your help..
From Philippines, Cebu
From Philippines, Cebu
Dear Jogul,
Warm welcome to our EHS forum. Please find the attached fire alarm-related documents and inspection checklist for your reference. Let us know if you need any further help.
Please write/ask a question clearly and correctly; don't confuse our EHS members. In the subject, you mentioned you need a smoke detector and manual pull station checklist. Inside the checklist for this fire alarm equipment, specify exactly what you need. I hope you take this positively and come forward.
Thanks & Be safe,
Raghu
From United States, Fpo
Warm welcome to our EHS forum. Please find the attached fire alarm-related documents and inspection checklist for your reference. Let us know if you need any further help.
Please write/ask a question clearly and correctly; don't confuse our EHS members. In the subject, you mentioned you need a smoke detector and manual pull station checklist. Inside the checklist for this fire alarm equipment, specify exactly what you need. I hope you take this positively and come forward.
Thanks & Be safe,
Raghu
From United States, Fpo
Hi,
Please find one more related to fire alarm.
Dear Ragu,
Thank you for the documents, which are useful for us. Also, your document related to fire hydrants was too good and useful. Keep on sharing, so we can learn from different angles too.
From India, Delhi
Please find one more related to fire alarm.
Dear Ragu,
Thank you for the documents, which are useful for us. Also, your document related to fire hydrants was too good and useful. Keep on sharing, so we can learn from different angles too.
From India, Delhi
Dear all , Kindly guide : Where flameproof MCP , HOOTERS required ( Selection Criteria). As cost of Flame proof is too high. so it can be affordable at selected places. Regards. Abhay
From India, Mumbai
From India, Mumbai
Dear Abhay,
Please see the attached fire alarm-related PPT slide/page #15 to get a solution regarding your (flameproof MCP) query. Let me know.
Note: I know it may not fully fulfill your query, but it may help in some way.
Thanks & Besafe,
Raghu
From United States, Fpo
Please see the attached fire alarm-related PPT slide/page #15 to get a solution regarding your (flameproof MCP) query. Let me know.
Note: I know it may not fully fulfill your query, but it may help in some way.
Thanks & Besafe,
Raghu
From United States, Fpo
Dear Jatinder Dubey,
Please follow the below-mentioned guidelines; it will help to create a perfect checklist for fire extinguishers:
- Confirm the extinguisher is visible, unobstructed, and in its designated location.
- Verify the locking pin is intact and the tamper seal is unbroken. Examine the extinguisher for obvious physical damage, corrosion, leakage, or a clogged nozzle.
- Confirm the pressure gauge or indicator is in the operable range or position, and lift the extinguisher to ensure it is still full.
- Make sure the operating instructions on the nameplate are legible and facing outward.
- Check the last professional service date on the tag. (A licensed fire extinguisher maintenance contractor must have inspected the extinguisher within the past 12 months.)
- Initial and date the back of the tag.
Note: Check your subject and message.
Thank you.
From United States, Fpo
Please follow the below-mentioned guidelines; it will help to create a perfect checklist for fire extinguishers:
- Confirm the extinguisher is visible, unobstructed, and in its designated location.
- Verify the locking pin is intact and the tamper seal is unbroken. Examine the extinguisher for obvious physical damage, corrosion, leakage, or a clogged nozzle.
- Confirm the pressure gauge or indicator is in the operable range or position, and lift the extinguisher to ensure it is still full.
- Make sure the operating instructions on the nameplate are legible and facing outward.
- Check the last professional service date on the tag. (A licensed fire extinguisher maintenance contractor must have inspected the extinguisher within the past 12 months.)
- Initial and date the back of the tag.
Note: Check your subject and message.
Thank you.
From United States, Fpo
"FIRE IS A GOOD SERVANT", BUT.....VERY BAD MASTER. Prakash Nandan. Manager Security & Fire.
From India, Nashik
From India, Nashik